![background image](/files/792619/content/doc009.png)
Master MLs™ 500, 503, 3500, 3503, Mastertig MLs™ 3000, 3003, 4000, 4003 / 0649– 9
© keMppi oy
1
2
3
1
2
3
4
5
6
7
8
3.2.2.1. Indicator lights
1. Power On
2. Thermal overload of power source
3. Wrong mains voltage, over or under-voltage
3.2.2.2. MMA welding panel MEL
1. Remote/local control switch
2. Welding current potentiometer
3. Contact TIG welding
4. MMA welding
5. Arc force
6. Hot start
7. Digital display and amperage/voltage switch
8. Welding current table