Fireplace installation, Continued – Desa (V)K36EN SERIES User Manual

Page 15

Advertising
background image

www.desatech.com

111924-01D

15

2. Attach green ground wire from power cord to blower housing

using screw provided (see Figure 25, page 14). Tighten screws

securely.

3. Place the blower against the lower rear wall of the firebox outer

wrapper with the exhaust port directed upward. The blower will

fit inside the back opening and be held in position against the

back wall by the magnets (see Figure 25, page 14).

4. Be certain that all wire terminals are securely attached to ter-

minals on blower motor and that the screw retaining the green

ground wire is tight.

5. Mount speed control box to switch bracket by placing the plastic

control shaft forward through the opening in the switch bracket

(see Figure 26).

6. While supporting speed control, secure control shaft with lock

nut by pushing and turning lock nut with pliers clockwise until

it is tight against front panel. Place control knob provided on

shaft.

7. Turn on power to duplex outlet if previously turned off per the

warning in column 2, page 14.

8. Plug in blower power cord.

a. If your firebox is installed as a freestanding unit with an

accessory mantel, determine whether the power cord will

exit the left side or the right side of the firebox. Route power

cord through exit hole and plug the power cord into a wall

receptacle near the firebox.

b. If your firebox installation is recessed and/or pre-wired, plug

the power cord into the duplex outlet provided. Refer to your

firebox owner’s manual for instructions on wiring the duplex

outlet.

CAUtION: Never touch the blower wheel while in

operation.

9. Check to make sure that the power cord is completely clear of

the blower wheel and that there are no other foreign objects in

blower wheel. Turn blower on and check for operation. Turn

blower off by turning knob fully counterclockwise before

continuing.

10. Peel off the backing paper and stick the supplied wiring diagram

decal on the firebox bottom approximately 12" in front of the

blower (see Figure 27).

FIREPLACE INSTALLATION

Continued

Figure 26 - Attaching Speed Control to Firebox

Speed Control

Control Shaft

Locknut

Control Knob

Switch

Bracket

Duplex Outlet (Located

underneath firebox

floor against lower right

outside wall)

Blower

Plug-In

Va

ria

ble

Fa

n S

wit

ch

Wh

ite

Wh

ite

Bla

ck

Gre

en

On

110

/11

5

V.A

.C

.

BlowerMoto

r

Bla

ck

Bla

ck

Bla

ck

Off

Figure 27 - Location of Wiring Diagram Decal (Model May

Vary From Illustration)

Wiring Diagram Decal

12" in Front of Blower

Model bkT Installation

Note:

When installing the BKT thermostatically-controlled blower,

you must first secure the thermal switch bracket to the blower if it

has not already been factory installed.
1. Place the green ground wire with ring terminal between the

bottom hole on the thermal switch bracket and the top ear hole

on the blower assembly. Insert the Phillips screw into all three

pieces and tighten securely (see Figure 28).

2. Connect wire harness and power cord terminals. Connect the

blue jumper wire to the blower motor terminal and the right

side terminal of the thermal switch. Connect the black wire to

the left side of the thermal switch and the white wire to the

other remaining blower motor terminal.

Note:

The power cord outer insulation sleeve may have to be

stripped slightly to allow enough wire length to reach and make

all connections. DO NOT trim excessive length away. Just enable

enough to make all connections securely.

Thermodisc

Figure 28 - Blower Model BKT

Air Flow Direction

Route BKT Blower

Through This Area

Magnets

Blower

Location

Side View Firebox Bottom

Black

Wire

Phillips

Screw

Blue Wire

Ring Terminal

on Green Wire

White Wire

Thermal Switch

Thermal

Switch

Bracket

Power Cord

Air Flow

Direction

Magnetic

Strips