INSPECTING bURNERS

Check pilot flame pattern and burner flame patterns often.

PILOT ASSEMbLY

The pilot assembly is factory preset for the proper flame. Altera-

tions may have occurred during shipping and handling. The pilot

is located on the back right hand side of the burner.

The flame must envelope 1/4" of top of the ignitor/sensor and

grounding stem.

If your pilot assembly does not meet these requirements:
• Turn the adjustment screw marked PILOT clockwise to decrease

or counterclockwise to increase the flame to proper size (see

Figure 47, page 22). Do not remove the adjustment screw.

• see Troubleshooting, page 25

bURNER FLAME PATTERN

Burner flames will be steady; not lifting or floating. Flame patterns

will be different from unit to unit and will vary depending on instal-

lation type and weather conditions.

If the vent configuration is installed incorrectly, the flames will lift

or "ghost". This can be dangerous. Inspect the flames after instal-

lation to ensure proper installation and performance.

Figure 50 shows a typical flame pattern.

If burner flame pattern differs from that described:
• turn fireplace off (see To Turn Off Gas to Appliance, page 22)

• see Troubleshooting, page 25

Figure 50 - Typical Flame Pattern

Pilot Burner

Ignitor/Sensor

Figure 49 - Correct Pilot Flame Pattern

Sensing Rod

CLEANING AND

MAINTENANCE

WARNING: turn off fireplace and let cool before

cleaning.

CAUtION: You must keep control areas, burners, and

circulating air passageways of fireplace clean. Inspect

these areas of fireplace before each use. Have fireplace

inspected yearly by a qualified service person. Fireplace

may need more frequent cleaning due to excessive lint

from carpeting, bedding material, pet hair, etc.

GLASS DOOR

WARNING: Handle glass door panel with care. Do

not strike, slam, or otherwise abuse glass. Do not op-

erate fireplace with the glass door removed, cracked,

or broken.

WARNING: Do not use abrasive cleaners as this

may damage glass. Use a nonabrasive household glass

cleaner to clean glass. Do not clean glass when hot.

Glass must be cleaned periodically. During start-up it is normal for

condensation to form on the inside of the glass causing lint, dust,

and other airborne particles to cling to the glass surface. During

initial start-up a slight film may form on the glass due to paint cur-

ing. The glass should be cleaned several times with a non-ammonia,

nonabrasive household cleaner and warm water after the first two

weeks of operation. Thereafter, clean the glass two or three times

during each heating season, depending on the usage and circum-

stances present. Refer to Removing/Replacing Glass Door on page

18 of this manual when removing glass door for cleaning.

WARNING: Only parts supplied by the manufacturer

should be used when replacing broken or damaged

glass door panel (see Replacement Parts, page 27).

This glass door panel is a complete unit. No substitute

materials may be used.

CAUtION: Wear gloves and safety glasses while

handling or removing broken glass. Do not remove if

glass is hot. keep children and pets away from glass.

If glass has been broken, carefully remove glass door (see Remov-

ing/Replacing Glass Door, page 18). Vacuum all glass pieces with

a shop vac.

CAUtION: Do not vacuum if pieces are hot.

Use only the tempered glass door replacement intended for this

fireplace (see Replacement Parts, page 27 for detail on ordering).

No substitutions may be made. See Removing/Replacing Glass

Door, page 18 for instructions for replacing glass door.

WARNING: Do not operate fireplace with the glass

door removed, cracked, or broken.

Advertising