Troubleshooting – Desa (V)K36EN SERIES User Manual

Page 26

Advertising
background image

www.desatech.com

111924-01D

26

TROUbLEShOOTING

Continued

WARNING: If you smell gas

• Shut off gas supply.

• Do not try to light any appliance.

• Do not touch any electrical switch; do not use any phone in your building.

• Immediately call your gas supplier from a neighbor’s phone. Follow the gas

supplier’s instructions.

• If you cannot reach your gas supplier, call the fire department.

POSSIBLE CAUSE

1. Metal expanding while heating or con-

tracting while cooling

1. Residues from manufacturing processes

and logs curing

1. Gas leak. See Warning statement at

top above

2. Control valve defective

1. Foreign matter between control valve

and burner

2. Gas leak. See Warning statement at

top above

1. Flame impingement on logs

2. Debris around burner air mixer

1. Improper log placement

2. Air holes at burner inlet blocked

3. Burner flame holes blocked

4. Improper venting or excessive blockage

5. Excessive amounts of embers and pan

material

ObSERVED PRObLEM

Fireplace produces a clicking/ticking noise

just after burner is lit or shut off

Slight smoke or odor during initial operation

Gas odor even when control knob is in OFF

position

Gas odor during combustion

Glass soots

Dark residue on logs or inside of fireplace

REMEDY

1. This is normal with most fireplaces.

If noise is excessive, contact qualified

service person

1. Problem will stop after a few hours of

operation

1. Locate and correct all leaks (see Check-

ing Gas Connections, page 17)

2. Replace control valve

1. Take apart gas tubing and remove for-

eign matter

2. Locate and correct all leaks (see Connect-

ing Fireplace to Gas Supply, page 17)

1. Adjust the log set so that the flame does

not excessively impinge on it

2. Inspect the opening at the base of the

burner to see that it is NOT packed with

any type of material

1. Properly locate logs (see log placement

sections on page 20)

2. Clean out air holes at burner inlets. Pe-

riodically repeat as needed

3. Remove blockage or replace burner

4. Have the vent system inspected, includ-

ing the termination cap. Remove any

restrictions or obstruction

5. Clear excess embers until a minimum

gap of 1/2" remains under the grate