Wiring diagram, Fireplace installation, Continued – Desa (V)K36EN SERIES User Manual

Page 21: Pilot gas line pilot burner

Advertising
background image

www.desatech.com

111924-01D

21

FIREPLACE INSTALLATION

Continued

3. Activate the remote handset battery by removing the insulating

tab on the back of the handset (see Figure 46). The battery is

included pre-installed.

4. Once the battery is activated the unit is ready to use.

5. Close lower louver panel.

Figure 46 - Installing Battery into Back of Handset

Pull to Remove

Insulation Tab

Battery Cover

12 Volt Battery

Back of

Handset

Robertshaw

MODEL

SP745 IGNITION CONTROL

STEP DOWN

TRANSFORMER

PV

GN
D

PV/MV

TR

MV

TH

IG

N

EV2

INCOMING MAIN

GAS SUPPLY

EV1

GAS LINE TO

BURNER

24V AC

120V AC

INCOMING

120V AC

(FUSE BOX

OR BREAKER)

OFF

ON

(SUPPLIED)

WALL SWITCH

GREEN

BLACK

WHITE

120v, 60Hz, 0.7A

ELECTRICAL RATING:

BLACK

WHITE

GREEN

OPTIONAL
REMOTE

CONTROL

WIRING DIAGRAM

Pilot Gas

Line

Pilot

Burner

Advertising