Venting installation instructions, Continued – Desa (V)K36EN SERIES User Manual

Page 8

Advertising
background image

www.desatech.com

111924-01D

8

Figure 10 - Installing Horizontal Vent Cap

(Noncombustible Exterior)

Wood Screw

Vent Cap

Apply Mastic to

All Four Sides

VENTING INSTALLATION

INSTRUCTIONS

Continued

2. Direct vent pipe sections and components are designed with

special twist-lock connections.

twist-Lock Procedure:

The female ends of the pipes have

locking lugs (indentations). These lugs will slide straight into

matching slots on the male ends of adjacent pipes. Push pipe

sections together and twist one section clockwise approxi-

mately one-quarter turn until the sections are fully locked (see

Figure 8). Note: Horizontal runs of vent must be supported

every three feet. Use wall straps for this purpose.

3. Use a 45° elbow to connect venting system to fireplace flue

collar. The elbow is designed to be twist-locked onto the flue

collar as described in step 2. IMPORTANT: Do not attempt

to alter the configuration of the elbow by cutting, twisting,

bending, etc.

4. Assemble the desired combination of pipe and elbows to the

fireplace. If there are long portions of venting run, pre-as-

sembled pipe sections may be installed as subassemblies for

convenience.

5. Carefully determine the location where the vent pipe assembly

will penetrate the outside wall. The center of the hole should

line up with the center-line of the horizontal vent pipe. Mark the

wall for a 10

3

/

4

" x 10

3

/

4

" square hole. Cut and frame the square

hole in the exterior wall where the vent will be terminated. If

the wall being penetrated is constructed of noncombustible

material, such as masonry block or concrete, a 8

1

/

2

" hole with

zero clearance is acceptable (see Figure 9).

WARNING: Do not recess vent termination into any

wall. this will cause a fire hazard.

6.

Noncombustible Exterior Wall:

Position the horizontal vent

cap in the center of the 8

1

/

2

" round hole and attach to the

exterior wall with four wood screws provided. Before attach-

ing the vent cap to exterior wall, run a bead of non-hardening

mastic (pliable sealant) around the outside edges to make a seal

between it and the outside wall. Note: The four wood screws

provided should be replaced with appropriate fasteners for

stucco, brick, concrete, or other types of sidings.

Combustible Exterior Wall:

For vinyl siding, stucco, or wood

exteriors, a siding standoff must be installed between the vent

cap and exterior wall. The siding standoff prevents excessive

heat from damaging the siding materials. Siding material

must be cut to accommodate standoff. Bolt the vent cap to the

standoff. Apply non-hardening mastic around outside edge of

standoff. Position the standoff/cap assembly in the center of

the 10

3

/

4

" square hole and attach to exterior wall with wood

screws provided (see Figure 11, page 9). The siding standoff

must sit flush against the exterior fascia material.

Figure 8 - Vent Pipe Connections

Female

Locking Lugs

Male

Slots

(Framing

Detail)

10

3

/

4

"

(27.3 cm)

10

3

/

4

" Inside Framing

(27.3 cm)

10

3

/

4

"

(27.3 cm)

8

1

/

2

"

(21.6 cm)

Vent Opening

Combustible Wall

Vent Opening

Noncombustible Wall

Figure 9 - Vent Opening Requirements

Center

of Hole