Wire direct wire connection, Remove center screw, Connect ground wire – Maytag WED4890BQ Installation User Manual
Page 11: Connect remaining wires, Connect neutral ground wire and neutral wire, Prepare your 3-wire cable for direct connection, Connect wires to terminal block
11
3-wire Direct Wire Connection
Use where local codes permit connecting cabinet-ground
conductor to neutral wire.
B
5.
Remove center screw
Remove center terminal block screw (B).
7.
Connect ground wire
A
F
Connect ground wire (green or bare) (F) of direct wire cable
to external ground conductor screw (A). Tighten screw.
Place hooked ends of remaining direct wire cable wires under
outer terminal block screws (hooks facing right). Squeeze hooked
ends together and tighten screws. Finally, reinsert tab of terminal
block cover into slot of dryer rear panel. Secure cover with hold-
down screw. Now, go to “Venting Requirements.”
8.
Connect remaining wires
B
C
E
6.
Connect neutral ground wire and
neutral wire
Connect neutral ground wire (E) and place hooked end (hook
facing right) of neutral wire (white or center wire) (C) of direct
wire cable under center screw of terminal block (B). Squeeze
hooked ends together and tighten screw.
Direct wire cable must have 5 ft. (1.52 m) of extra length so
dryer may be moved if needed.
Strip 3
1
/
2
" (89 mm) of outer covering from end of cable. Strip
insulation back 1" (25 mm). If using 3-wire cable with ground
wire, cut bare wire even with outer covering. Shape wire ends
into hooks.
1"
(25 mm)
3½"
(89 mm)
3.
Prepare your 3-wire cable for direct
connection
To connect wires to terminal block, place hooked end of wire
under terminal block screw (facing to the right), squeeze hooked
end together, and tighten screw.
4.
Connect wires to terminal block
5.
Prepare to connect neutral
ground wire and neutral wire
E
A
B
Remove center terminal block screw (B). Remove neutral
ground wire (E) from external ground conductor screw (A).