Wire power supply cord connection, Connect remaining wires, Connect ground wire – Maytag WED4890BQ Installation User Manual

Page 9: Remove center screw, Connect neutral ground wire and neutral wire

Advertising
background image

9

3-wire Power Supply Cord Connection

Use where local codes permit connecting cabinet-ground

conductor to neutral wire.

A

B

D

C

E

F

G

A. 3-wire receptacle (NEMA type 10-30R)

B. 3-wire plug

C. Neutral prong

D. Spade terminals with upturned ends

E. 3/4" (19 mm) UL listed strain relief

F. Ring terminals

G. Neutral (white or center wire)

6.

Connect remaining wires

Connect remaining wires to outer terminal block screws.

Tighten screws. Finally, reinsert tab of terminal block cover

into slot of dryer rear panel. Secure cover with hold-down

screw. Now, go to “Venting Requirements.”

A

F

Connect ground wire (F) (green or bare) of power supply cord

to external ground conductor screw (A). Tighten screw.

5.

Connect ground wire

Remove center terminal block screw (B).

B

3.

Remove center screw

4-wire Power Supply Cord Connection

Remove center terminal block screw (B). Remove neutral

ground wire (E) from external ground conductor screw (A).

A

E

B

3.

Prepare to connect neutral

ground wire and neutral wire.

B

C

E

4.

Connect neutral ground

wire and neutral wire

Connect neutral ground wire (E) and neutral wire (white or

center) (C) of power supply cord under center terminal block

screw (B). Tighten screw.

IMPORTANT:

A 4-wire connection is required for mobile

homes and where local codes do not permit the use of 3-wire

connections.

A

B

F

E

G

D

C

A. 4-wire receptacle (NEMA type 14-30R)

B. 4-prong plug

C. Ground prong

D. Neutral prong

E. Spade terminals with upturned ends

F. 3/4" (19 mm) UL listed strain relief

G. Ring terminals