1.

Prepare to connect neutral

ground wire and neutral wire

A

E

B

Remove center terminal block screw (B). Remove neutral ground

wire (E) from external ground conductor screw (A).

B

C

E

2.

Connect neutral ground wire

and neutral wire

Connect neutral ground wire (E) and neutral wire (white or

center wire) (C) of power supply cord or cable under center

terminal block screw (B). Tighten screw.

3.

Connect remaining wires

Place hooked ends of remaining wires under outer terminal

block screws (hooks facing right). Tighten screws.

A

G

4.

Connect external ground wire

Connect a separate copper ground wire (G) from the external

ground conductor screw (A) to an adequate ground. Finally,

reinsert tab of terminal block cover into slot of dryer rear panel.

Secure cover with hold-down screw. Now, go to “Venting

Requirements.”

Optional 3-wire Connection

You must verify with a qualified electrician that this

grounding method is acceptable before connecting.

7.

Connect remaining wires

Place hooked ends of remaining direct wire cable wires

under outer terminal block screws (hooks facing right). Squeeze

hooked ends together and tighten screws. Finally, reinsert tab of

terminal block cover into slot of dryer rear panel. Secure cover

with hold-down screw. Now, go to “Venting Requirements.”

C

B

Place hooked end of neutral wire (white or center) (C) of direct

wire cable under center terminal block screw (B). Squeeze

hooked end together. Tighten screw.

6.

Connect neutral wire

Advertising