4.3 On GPIO pins

There are three GPIO status lines, see Table 1: Connector functions on page 5. One is a
general card status alarm; the connection to ground is open when the card has either
detected a critical fault or is powered off, the connection to ground is closed when the
module is in normal operation. This GPIO pin effectively follows the status LED described in
Table 2 in the previous chapter.

Then there are two alarms that reflect LEDs 3 and 4 described in Table 2; a green LED
gives a closed connection to the ground pin, while a red or orange LED gives an open
connection to the ground pin.