HD-TD-3GMX-2 / HD-TD-3GDX-2 and SDI-TD-3GMX-5 / SDI-TD-3GDX-5

Rev. F


nevion.com | 30

HD2 Stream

HD/SD video

stream empty or

not present at all

HD video stream
containing SDs is
present, but the 4
SDs are not all
present

HD/SD video

stream is present.

If it is an HD

containing 4 SDs,

all of them are

present

Module has

no power

Input

Input not locked to

a valid 3G signal

Input locked to a

valid 3G signal,

but it is a fallback

signal (check

main signal)

Input locked to a

valid 3G signal.

If the setup

includes two

physical inputs,

input is taken

from main

Module has

no power

Table 7 LED HDI-TD-3GM/DX-2

Exceptions for the LEDS:

The locate command will make all four LEDs blink orange and off
synchronously. The operation of the card will not be affected.

If only the Card status LED blinks between orange and off, this means that the
mounted DWDM module is either too hot or too cold to output the correct
wavelength, and that the output has temporarily been shut off. If this occurs
other than for a short moment immediately after start-up, the thermoelectric
element on the DWDM module is most likely broken.

Firmware upgrades will activate running lights on the LEDs after the firmware
download has finished. Do not remove power to the card when running lights
are active, the card is unpacking and installing the new firmware. The modules
will automatically reboot after a successful upgrade.