4. Troubleshooting

If the UPS system does not operate correctly, please solve the problem by using the table
below.

Symptom

Possible cause

Remedy

No indication and alarm even
though the main is normal.

The AC input power is not
connected well.

Check if input power cord
firmly connected to the

mains.

The AC input is connected
to the UPS output.

Plug AC input power cord
to AC input correctly.

The icon

and the warning

code

flashing on LCD display

and alarm is sounding every

second.

EPO function is activated.

Set the circuit in closed

position to disable EPO
function.

The icon

and

flashing

on LCD display and alarm is
sounding every second.

Line and neutral
conductors of UPS input
are reversed.

Rotate mains power socket
by 180° and then connect
to UPS system.

The icon

and

flashing

on LCD display and alarm is

sounding every second.

The external or internal
battery is incorrectly

connected.

Check if all batteries are
connected well.

Fault code is shown as 27 and the

icon

is lighting on LCD

display and alarm is continuously
sounding.

Battery voltage is too high
or the charger is fault.

Contact your dealer.

Fault code is shown as 28 and the

icon

is lighting on LCD

display and alarm is continuously
sounding.

Battery voltage is too low
or the charger is fault.

Contact your dealer.

The icons of

and

are flashing on LCD display and
alarm is sounding twice every
second.

UPS is overload

Remove excess loads from

UPS output.

UPS is overloaded. Devices
connected to the UPS are
fed directly by the

electrical network via the
Bypass.

Remove excess loads from
UPS output.

After repetitive overloads,
the UPS is locked in the

Bypass mode. Connected
devices are fed directly by
the mains.

Remove excess loads from
UPS output first. Then shut

down the UPS and restart
it.