background image

DXP V1616 User Manual 47

DAT2

1

0-15

Show

customers

and

manufacturer information initial
column

DAT3

1

0-15 Show customers and device
information initial column

DAT4

1

0(no use)

Set customer LOGO display parameter is default for opening

customer LOGO display

Common communication commands

<T addr sn cmd data1 data2 data3 data4 cs >

cs = addr+sn+cmd+data1+data2+data3+data4

<T0001701002020085> //switch input2->output2

<T0001701003020086> //switch input2->output3

<T0001701004030088> //switch input3->output4

<T000170100e0a0099> //switch input10->output14

<T000170100e00008F> //close output way14

<T00017010ff040084> //switch input4->all outputs

<T0001701106000088> //Read input channel that output way6

correspond to

<F00017011060d0095> //Back input13->output6

Note

Compatible with Extron matrix (MVX
1616 VGA A) agreement.