2.4 External Alarm In/Out Connection

Alarm output connection

Please note the usage of jumper JJ1. If you use DC, either connection is OK. We suggest you

use DC under 12V, 1A.

If you use AC, please open the jumper. There are 4 jumpers (JJ1, JJ2, JJ3 and JJ4) on DVR

main board, corresponding with 4 alarm output. The default is closed.

Warning: If you use AC input for relay output, please open the jumpers.

Alarm input port (drp node):

G (GND): Connect the GND of sensor.

1~8: Alarm input, support normal

open/normal close.

0: Reserved.

Alarm output:

1G~4G: 4 relay output.