TLX Matrix Switch SNMP Traps Manual

7

Rev. E - July, 2015

(SFP) WARNINGS

High Temperature Warning

Begin and Clear

An SFP module has the ability to monitor and trigger an alarm on a high or low temperature reading. This
ability is internal to the SFP and is part of the digital diagnostic interface common to many SFPs. This
notification is sent when bit 7 of byte 116 in the real-time diagnostic registers changes from 0 to 1 (Begin) or
from a 1 to a 0 (Clear).

This bit is set when the internal temperature of the SFP exceeds the high temperature warning level. The
SFP temperature is stored at bytes 96 & 97 of the SFP diagnostic register table.

Begin OID:

1,3,6,1,4,1,17658,2,2,2,0,21

Clear OID:

1,3,6,1,4,1,17658,2,2,2,0,22

Objects:

1: sfpLabel
2: sfpTemperature
3: sfpThresholdHighTempWarning

4: sysContact
5: sysDescr
6: sysLocation
7: sysName

Low Temperature Warning

Begin and Clear

An SFP module has the ability to monitor and trigger an alarm on a high or low temperature reading. This
ability is internal to the SFP and is part of the digital diagnostic interface common to many SFPs. This
notification is sent when bit 6 of byte 116 in the real-time diagnostic registers changes from 0 to 1 (Begin) or
from a 1 to a 0 (Clear).

This bit is set when the internal temperature of the SFP falls below the low temperature warning level. The
SFP temperature is stored at bytes 96 & 97 of the SFP diagnostic register table.

Begin OID:

1,3,6,1,4,1,17658,2,2,2,0,23

Clear OID:

1,3,6,1,4,1,17658,2,2,2,0,24

Objects:

1: sfpLabel
2: sfpTemperature
3: sfpThresholdLowTempWarning

4: sysContact
5: sysDescr
6: sysLocation
7: sysName

High Vcc Warning

Begin and Clear

An SFP module has the ability to monitor and trigger an alarm on a high or low Vcc voltage reading. This
ability is internal to the SFP and is part of the digital diagnostic interface common to many SFPs. This
notification is sent when bit 5 of byte 116 in the real-time diagnostic registers changes from 0 to 1 (Begin) or
from a 1 to a 0 (Clear).

This bit is set when the internal supply voltage to the SFP exceeds the high voltage warning level. The SFP
voltage is stored at bytes 98 & 99 of the SFP diagnostic register table.

Begin OID:

1,3,6,1,4,1,17658,2,2,2,0,25

Clear OID:

1,3,6,1,4,1,17658,2,2,2,0,26

Objects:

1: sfpLabel
2: sfpTemperature
3: sfpThresholdHighVccWarning

4: sysContact
5: sysDescr
6: sysLocation
7: sysName