TLX Matrix Switch SNMP Traps Manual

3

Rev. E - July, 2015

ALARMS

High Temperature Alarm

Begin and Clear

An SFP module has the ability to monitor and trigger an alarm on a high or low temperature reading. This
ability is internal to the SFP and is part of the digital diagnostic interface common to many SFPs. This
notification is sent when bit 7 of byte 112 in the real-time diagnostic registers changes from 0 to 1 (Begin) or
from a 1 to a 0 (Clear).

This bit is set when the internal temperature of the SFP exceeds the high temperature alarm level. The SFP
temperature is stored at bytes 96 and 97 of the SFP diagnostic register table.

Begin OID:

1,3,6,1,4,1,17658,2,2,2,0,1

Clear OID:

1,3,6,1,4,1,17658,2,2,2,0,2

Objects:

1: sfpLabel
2: sfpTemperature
3: sfpThresholdHighTempAlarm

4: sysContact
5: sysDescr
6: sysLocation
7: sysName

Low Temperature Alarm

Begin and Clear

An SFP module has the ability to monitor and trigger an alarm on a high or low temperature reading. This
ability is internal to the SFP and is part of the digital diagnostic interface common to many SFPs. This
notification is sent when bit 6 of byte 112 in the real-time diagnostic registers changes from 0 to 1 (Begin) or
from a 1 to a 0 (Clear).

This bit is set when the internal temperature of the SFP exceeds the high temperature alarm level. The SFP
temperature is stored at bytes 96 and 97 of the SFP diagnostic register table.

Begin OID:

1,3,6,1,4,1,17658,2,2,2,0,3

Clear OID:

1,3,6,1,4,1,17658,2,2,2,0,4

Objects:

1: sfpLabel
2: sfpTemperature
3: sfpThresholdLowTempAlarm

4: sysContact
5: sysDescr
6: sysLocation
7: sysName

High Vcc Alarm

Begin and Clear

An SFP module has the ability to monitor and trigger an alarm on a high or low Vcc voltage reading. This
ability is internal to the SFP and is part of the digital diagnostic interface common to many SFPs. This
notification is sent when bit 5 of byte 112 in the real-time diagnostic registers changes from 0 to 1 (Begin) or
from a 1 to a 0 (Clear).

This bit is set when the internal temperature of the SFP exceeds the high temperature alarm level. The SFP
temperature is stored at bytes 98 and 99 of the SFP diagnostic register table.

Begin OID:

1,3,6,1,4,1,17658,2,2,2,0,5

Clear OID:

1,3,6,1,4,1,17658,2,2,2,0,6

Objects:

1: sfpLabel
2: sfpTemperature
3: sfpThresholdHighVccAlarm

4: sysContact
5: sysDescr
6: sysLocation
7: sysName