TLX320 HARDWARE ALARMS (Alarm Contacts)

Power Supply 1 Failure

Begin and Clear

Contact 1

TLX320 Power Supply 1 has failed (Begin) or is restored (Clear).

Begin OID:

1,3,6,1,4,1,17658,3,14,0,1

Clear OID:

1,3,6,1,4,1,17658,3,14,0,2

Objects:

1: tlxSwitchPSlabel
2: tlxSwitchPSstatus

3: sysContact
4: sysDescr
5: sysLocation
6: sysName

Power Supply 2 Failure

Begin and Clear

Contact 2

TLX320 Power Supply 2 has failed (Begin) or is restored (Clear).

Begin OID:

1,3,6,1,4,1,17658,3,14,0,3

Clear OID:

1,3,6,1,4,1,17658,3,14,0,4

Objects:

1: tlxSwitchPSlabel
2: tlxSwitchPSstatus

3: sysContact
4: sysDescr
5: sysLocation
6: sysName

Low Fan Speed

Begin and Clear

Contact 3

A fan in the Fan Tray has failed (Begin) or is restored (Clear).

Begin OID:

1,3,6,1,4,1,17658,3,14,0,5

Clear OID:

1,3,6,1,4,1,17658,3,14,0,6

Objects:

1: sysContact
2: sysDescr
3: sysLocation
4: sysName

Temperature Warning

Begin and Clear

Contact 4

The system has detected a temperature that is above the preset warning threshold (Begin) or is now below
the preset alarm threshold (Clear).

Begin OID:

1,3,6,1,4,1,17658,3,14,0,7

Clear OID:

1,3,6,1,4,1,17658,3,14,0,8

Objects:

1: sysContact
2: sysDescr
3: sysLocation
4: sysName