If using the fully Adjustable Clamping Pads, clamp the Clamshell to the tube as

follows:

Rough center and square the Clamshell by tightening the Clamping Pads

independently.

Check the center and squareness by eye.

The Adjustable Pads tend to square the Clamshell to the tube.

If additional precision in squaring is required, consult TRI TOOL Inc. about alternate

methods of squaring.

Fine center the Clamshell as you would a 4-jaw chuck.

Take measurements from tube OD to the Housing ID or use a dial indicator to sweep

around the tube’s outside diameter.

Adjust the four Clamping Pads so that the measurements at opposing Clamping

Pads are the same.

GENERAL MACHINING SEQUENCE

To set Tool Bits, go to ‘Tool Bit set-up’ later in this section, for set-up instructions.

Install the Air Motor into the drive socket and bolt it to the Clamshell.

There are 6 various orientations available so that clearance for the Air Motor may be

obtained.

Air Motor Alternate Positions