Power connection, Power connection – Verilink PRISM 3060-10 (34-00252.4) Product Manual User Manual

Page 21

Advertising
background image

Power Connection

13

The physical connection is a 6 -pin modular jack with the following pinout
assignments. The port is a serial RS232-level port configured for 8 bits, no parity,
and 1 stop bit.

Power
Connection

The unit is factory equipped with a standard three-prong AC cord and is fused at
1.0 ampere.

Remove power before checking fuses.

On power up, the board initialization sequence causes a delay. During this period, the
message on the front panel shows Calculating Checksum.

1

Connect the AC power cord to an appropriate AC power receptacle.

2

Set the rear panel power ON/ OFF switch to the ON position (labeled

l

). The green

power LED on the front panel should light after the LED initialization sequence
ends. If the indicators do not light, recheck the power connections and the primary
AC circuit breaker. Make sure the ON /OFF switch is in the ON position.

Table 2-6 SUPV Port Pinout

Pin

SUPV Port Interface

1

Control Out

2, 5

Signal Ground

3

Data Out

4

Data In

6

Control In