Alarms Screen

41

Alarms
Screen

The Alarms screen (Figure 4-4) allows viewing the alarm status of the network and
the DTE lines. The DTE Alarms field is described as follows.

NET Alarms

These status lines display the selected element’s current network /DTE signal alarm
state. Alarms are determined by the user-selectable thresholds listed in Table 4-2.

3060 DSU x.xx/x.xx

PRISM 3060

Date: MM/DD/YY

3060 DSU x.xx/x.xx

TXPORT Prism 3060-10

Time: HH:MM:SS

----------------------------------- ALARMS -------------------------------------

Element: [ ]

NET Alarms: NONE

DTE Alarms: OK

Current Threshold

Loss of Signal Seconds (LOSS) 0 5

Errored Seconds (ES) 2 45

Severely Errored Seconds (SES) 2 5

Unavailable Seconds (UAS) 0 0

Out of Frame Seconds (OOFS) 0 5

Remote Alarm Seconds (RAS) 0 0

AIS Seconds (AISS) 0 0

BPV Seconds (BPVS) 0 0

DTE LOS/OOF Seconds (LOSS) 0 0

Power Loss Seconds (PLS) 0 0

Reset Alarm Registers (RESET)

------------------------------------Messages------------------------------------

Local Screen

igure 4-4 Alarms Screen

Table 4-2 Alarm Indications

Alarm

Description

NONE

No alarm threshold has been exceeded, although
errors may exist that do not exceed thresholds.

ERRS

The Errored Seconds, Severely Errored Seconds, or
Bipolar Errored Seconds threshold is exceeded.

LOSS

The Loss Of Signal Seconds threshold is exceeded.

OOFS

The Out Of Frame Seconds threshold is exceeded.

RAIS

The Remote Alarm Seconds threshold is exceeded.

AISS

The Alarm Indication Seconds threshold is exceeded.

UAS

The Unavailable Seconds threshold is exceeded.

Advertising