Elapsed time, Bit errors, Errored seconds – Verilink PRISM 3060-10 (34-00252.4) Product Manual User Manual

Page 59: Line fault and loop status, Net/dte status, Near loops, Far loops, Elapsed time bit errors errored seconds % efs, Net /dte status near loops far loops

Advertising
background image

Maintenance Screen

51

Elapsed Time

Displays the amount of time elapsed since a timed test began or, if completed, the
total test time.

Bit Errors

Displays the total number of bit errors detected since the test began or since error
statistics were cleared (up to 999,999).

Errored Seconds

Displays the number of asynchronous errored seconds that have been detected
since the test began or since error statistics were last cleared. This parameter
includes bit error seconds and sync loss seconds.

% EFS

This ratio is derived from the number of error-free seconds divided by the number
of seconds accumulated in Elapsed Time.

Line Fault

and

Loop Status

The following fields are for display only. They reflect the selected test parameters and
the results of these tests only.

NET /DTE Status

Displays the fault status of the network and T1 DTE. They are indicators of current
fault conditions and do not indicate that alarm thresholds are exceeded. Status
indications are described in Table 4-3 on page 45.

Near Loops

Displays the loop status of the near element. If there are more near loops than fits
on one line, the field scrolls by pressing the spacebar.

Far Loops

Displays the loop status of the far element. If there are more far loops than fits on
one line, the field scrolls by pressing the spacebar.