Menu structure, Alarms screen, Menu structure alarms screen – Verilink PRISM 4051 (34-00253.2) Product Manual User Manual

Page 30

Advertising
background image

24

C

HAPTER

4: T

ERMINAL

O

PERATION

Menu Structure

The terminal interface opens
with a main menu allowing
four options: Alarms,
Maintenance, Configuration,
and Utilities (Figure 4 -2).
Each menu screen allows
accessing the local or far-end
menu screen.

If a keystroke is not made for ten minutes, the terminal interface automatically logs
off.

Alarms Screen

The Alarms screen (Figure 4- 3) allows viewing the current alarm status of the
network and the DTE lines.

Alarms

MAIN

MENU

Log

Log

Maintenance

Configuration

Utilities

Figure 4 -2 Menu Structure

DDS Network
Parameters

DTE Port
Parameters

Off

On

Figure 4 -3 Alarms Screen

4051 DDS 255.255/1.02 P R I S M 4 0 5 1 Date: 08/23/96

(Unit Address: 1) Time: 09:11:44

-------------------------------------- ALARMS ----------------------------------

NET Alarms: LOSS

DTE Alarms: NONE

Current Threshold

Loss of Signal Seconds (LOSS): 7874 5

Out of Service Seconds (OOSS): 0 0

Out of Frame Seconds (OOFS): 7874 0

Reset Alarm Registers: (RESET)

------------------------------------ Messages ----------------------------------

NET ALARM

Advertising