exceeded. Status indications are described in the NET and DTE Status fields.
Status indications are described in Table 4-4.

Near Loops

Displays the loop status of the near element.

Far Loops

Displays the loop status of the far element.

Configuration

Screen

The Configuration screens allow viewing and setting configuration parameters for
the network elements. Figure 4-10 shows the screens and where information about
them is located in the manual.

To send a new configuration to the unit, press Enter on one of the fields or exit the
screen. The underlined values are the factory default parameters.

Changing any of the configuration settings of an active 4051 causes a brief
synchronization loss.

Table 4-4 Status Indications

Status

Description

-------

No status is available

OK

No errors are currently detected.

LOS

A loss of signal condition exists.

OOF

An out of frame condition exists or OOF codes are received.

OOS

Out of Service codes are received.

DTR

DTR from the DTE device is false.

igure 4-10 Configuration Menu

DDS Network

Parameters

page 31

DTE Port

Parameters

page 32

Alarm

Parameters

page 33

Management

Parameters

page 34

Summary

page 36