Interface specifications – Westermo GDW-11 User Manual

Page 15

Advertising
background image

15

6615-2203

Interface specifications

Power

Rated voltage

12 to 48 VDC

Operating voltage

10 to 60 VDC

Rated current

350 mA @ 12 VDC
150 mA @ 24 VDC
75 mA @ 48 VDC

Rated frequency

DC

Inrush current I

2

t

0.05A

2

s

Startup current*

0.75A peak

Polarity

Reverse polarity protected

Connection

Detachable screw terminal

Connector size

0.2 – 2.5 mm

2

(AWG 24-12)

Isolation to

All other ports 3 kV

rms

50 Hz 1 min

Shielded cable

Not required

*

External supply current capability for proper startup

RS-232

Electrical specification

RS-232 V.24

Data rate

300 bit/s – 115.2 kbit/s

Data format

7 or 8 data bits, Odd, even or no parity, 1 or 2 stop bits

Protocol

Transparent

Retiming

Yes

Transmission range

15 m

Isolation to

Power port 3 kV

rms

50 Hz 1 min

Connection

9-pin D-sub female (DCE) and 5 pos Detachable screw terminal (DCE)

Connector size

Detachable screw terminal 0.2 – 2.5 mm

2

(AWG 24 – 12)

Shielded cable

Not required*

Conductive housing

Isolated to all other circuits

* Railway installation close to the rails.

For a cable located inside 3 m boundary and connected to this port, the use of shielded cable is recommended,

this is to minimise the risk of interference. The cable shield should be properly connected (360°) to an earthing

point within 1 m from this port.This earthing point should have a low impedance connection to the conductive

enclosure of the apparatus cabinet, or similar, where the unit is built-in.This conductive enclosure should be con-

nected to the earthing system of an installation and may be directly connected to the protective earth.