9

6615-2203

12

12

34

1234

Ratings and safety control drawing, GDW-11 485 EX

Power

(12 – 48) VDC; 350 mA

Ambient temperature

–25ºC ≤ Ta ≤ +50ºC

Maximum surface temperature Temperature class T4 (max 135ºC )
Ingress protection (IP)

IP21

Installation spacing

Minimum 25 mm above / below and minimum 10 mm
left / right

Antenna

Position Direction / description

Input / Output values

1

In/out / RF signal

Max RF power: 2 watt
Data rate:
CSD: up to 14.4 kbit/s
GPRS: up to 85.6 kbit/s

Shield

Signal ground

RS-232 (DB9, female)

Position Direction / description

Input / Output values

1

Out / Data Carrier Detect (DCD)

U

max

= ± 12 Vpk

I

max

= ± 60 mA

Data rate:
300 bit/s to 115.2 kbit/s

2

Out / Received Data (RD)

3

In / Transmitted Data (TD)

4

In / Data Terminal Ready (DTR)

5

– / Signal Ground (SG)

6

Out / Data Set Ready (DSR)

7

In / Request To Send (RTS)

8

Out / Clear To Send (CTS)

9

Out / Ring Indicator (RI)

RS-422/485 (4-pin screw terminal)

Position Direction / description

Input / Output values

1

In / R+ (RS-422/485 4-wire)

U

max

= ± 12 Vpk

I

max

= ± 60 mA

Data rate:
1200 bit/s
to 115.2 kbit/s

2

In / R– (RS-422/485 4-wire)

3

Out / T+ (RS-422/485 4-wire)
In/Out / T+ (RS-485 2-wire)

4

Out / T– (RS-422/485 4-wire)
In/Out / T+ (RS-485 2-wire)

Position Description

Input values

1

In / –VDC

U

in

= (10 – 60) VDC

Max I

in

= 0.4A @ 10 VDC

Max P

In

= Max 4 W

2

In / +VDC

Galvanically isolated via power transformer and optocoupler.

Capacitively isolated via 4700 pF capacitator rated 300 Vrms.

Advertising