Application examples – Westermo GDW-11 User Manual

Page 33

Advertising
background image

33

6615-2203

GSM

Network

NOTE: If no valid DTR signal can be provided by external application, the modems DSR signal can

be used to trig the transmission. Connect the DSR signal via a relay, or other potential
free contact, to the DTR signal. A 10 kohm pull down resistor should also be connected
between the DTR and a signal that is always low e.g. the DCD can be used if the modem
is used only for SMS sending:

DTR

DSR

DCD

Relay

External

application

10 kohm

May be required in harsh environments.

Application examples

GDW-11 connected to GDW-11 with DTR signal call

Configure the units

AT+CPIN=xxxx

If PIN code required

AT&F

Set the unit to factory default

AT&W

Store default settings

Set up the connection – The dialling modem

AT+CPBS=”SM”

Select phonebook as memory storage (this is default)

AT+CPBW=1,”nnn”

Store the number of the remote modem in the dialling GDW-11

AT&S0

Set DSR signal always high (if this signal is used to trig the DTR)

AT%D1

Activates automatic DTR dialling if DTR switches from low (OFF)
to high (ON).

AT&W

Save settings

Switch DTR from
OFF to ON

The modem will now dial the phone number stored in the first location of
the phonebook.

Set up the connection – The answering modem

ATA

Enter the answer command when RING comes from the network or
set up ATS0=1 to auto answer on 1 RING signal (or more than 1).