Data commands – Westermo GS-01 User Manual

Page 25

Advertising
background image

25

6195-2201

Data commands

+CBST – Bearer type selection

Command syntax:

AT+CBST= <speed>, <name>, <ce>

No data compression is provided and only asynchronous modem is supported (<name> = 0).

<speed>

Description

Modem type

0 (default)

Autobauding

None

1

300 bit/s

V.21

2

1 200 bit/s

V.22

3

1 200/75 bit/s

V.23

4

2 400 bit/s

V.22bis

5

2 400 bit/s

V.26ter

6

4 800 bit/s

V.32

7

9 600 bit/s

V.32

8

Specific

65

300 bit/s

V.110

66

1 200 bit/s

V.110

68

2 400 bit/s

V.110

70

4 800 bit/s

V.110

71

9 600 bit/s

V.110

<ce>

Connection element

0

Transparent only

1(default)

Non transparent only

2

Transparent preferred

3

Non transparent preferred

Application to GSM

AT+CBST=7,0,1

Ask for a bearer

GSM to application

OK

Bearer supported

Application to GSM

AT+CBST=81,0,0

Ask for a bearer

GSM to application

+CME ERROR: 4

Bearer not supported

This command applies to both outgoing and incoming data calls but in a different way.
For outgoing call the two parameters (e.g. <speed> and <ce>) apply, whereas for
incoming call only the <ce> parameter applies.

Note 1) as far as incoming calls are concerned, if <ce> is set to T only and the network

proposes NT only or vice versa then the call is released.

Note 2) older values 100 and 101 for <ce> are retained for compatibility purpose but shall

not be used anymore, values 2 and 3 shall be used instead.

Advertising