POWER UNIT INSTALLATION & START UP PROCEDURE

Fill the reservoir with automatic transmission fluid or any clean

hydraulic fluid having a viscosity index that is suitable for the

climatic conditions in which the unit will be operated. Recom-

mended operating temperature range is +20° F to +180° F.

GENERAL START UP INSTRUCTIONS

NOTE: The ports are marked on the casting ‘UP’ and ‘DN’.

When facing the power unit with the motor up, plug the right

hand, or ‘DN’ port. Jog the motor until oil flows from the left

hand, or ‘UP’ port. If oil does not flow from the ‘UP’ port, re-

verse the wire leads on the motor, and repeat. The pump is

now primed. Connect the hose (or tubing) to the ‘UP’ port and

tighten. Connect the other hose end to the blind end of a fully

retracted hydraulic cylinder. With the hose fitting loose, operate the power unit until oil (and

no air) bleeds from the fitting. Tighten the fitting. Refill the reservoir.