OPERATION AND SPECIFICATIONS

BEFORE STARTING

1. Fill the engine with the proper grade of

lubricating oil (see pg. 11) and to cor-

rect level (check dipstick).

2. Ensure there is an adequate supply of

clean fuel, per appropriate EPA stan-

dards.

3. Ensure that the air cleaner is firmly

attached, and that the air canister

seals and the hose clamps are prop-

erly sealed. If the restriction gauge

indicates an obstructed air flow, the air

cleaner element should be checked

and replaced as necessary.

4. Install the ground rod.

DESCRIPTION OF OPERATION

By operating the start switch, the fuel so-

lenoid is energized. The solenoid plunger

is drawn into the coil and activates the fue!

control linkage to RUN position. When the

engine starts, adequate engine oil pres-

sure at the oil pressure switch will maintain

the solenoid in the energized position. The

start switch should be released as soon as

the engine starts. A 10A inline fuse pro-

tects the solenoid from electrical damage.

LOW OIL PRESSURE SHUTOFF

SYSTEM

Should a low oil pressure condition occur

(less than 5 PSI), the pressure sending

unit breaks the circuit between the battery

and the fuel solenoid, allowing the spring

load to immediately move the fuel control

to the shutoff position.

HIGH COOLANT TEMPERATURE

SHUTOFF SYSTEM

Should a high coolant temperature condi-

tion occur, the temperature sending unit

breaks the circuit between the battery and

the fuel solenoid, allowing the spring load

to immediately move the fuel control to the

shutoff position.

TIONS

STARTING KUBOTA AND

ISUZU ENGINES

NOTE: The Kubota and Isuzu engines in-

clude a glow plug cold start assist system

on the control panel. Glow plugs are not

needed on a warm engine or if the ambi-

ent temperature is above 50 F. Do not use

starting fluid or ether.

1. Turn the ignition power switch to the

ON

position. Depress the glow plug button

for 3-5 seconds. NOTE: The glow plug

indicator lamp remains lit for as long as

the button is depressed, indicating that

electrical power is being supplied to the

glow plugs.

2. Push or rotate (as required) Start switch

until the engine starts. Release switch as

soon as the engine starts.

3. If engine fails to start it may be necessary

to cycle the glow plugs again.

NOTE: To prevent equipment damage, DO

NOT operate ignition switch for more than

10 seconds in the start position. If the en-

gine does not start in 10 seconds, wait 30

seconds and try the start sequence again.

Do not run the starter for more than 20

seconds continuously. Limit engine crank-

ing to 3 attempts with a 2 minute cool-

down between each attempt. After 3 at-

tempts allow starting system components

to cool to ambient temperature.

STOPPING KUBOTA AND

ISUZU ENGINES

1. Turn the ignition power switch to the

OFF

position. This immediately breaks the

circuit between the battery and the fuel

solenoid, allowing the fuel control sole-

noid to move to the shutoff position.

2. Disconnect the ground rod, and stow

within the trailer.

STARTING/STOPPING INSTRUCTIONS