Troubleshooting mpls te – H3C Technologies H3C S7500E Series Switches User Manual
Page 160

3-78
Tunnel1 current state: UP
Line protocol current state: UP
Description: Tunnel1 Interface
The Maximum Transmit Unit is 1500
Internet Address is 12.1.1.1/24 Primary
Encapsulation is TUNNEL, service-loopback-group not set
Tunnel source unknown, destination 3.3.3.3
Tunnel protocol/transport CR_LSP
Last 300 seconds input: 5 bytes/sec, 0 packets/sec
Last 300 seconds output: 5 bytes/sec, 0 packets/sec
34 packets input, 2856 bytes
0 input error
34 packets output, 2856 bytes
0 output error
Troubleshooting MPLS TE
Symptom:
OSPF TE is configured but no TE LSAs can be generated to describe MPLS TE attributes.
Analysis:
For TE LSAs to be generated, at least one OSPF neighbor must reach the FULL state.
Solution:
1) Perform
the
display current-configuration
command to check that MPLS TE is configured on
involved interfaces.
2) Perform
the
debugging ospf mpls-te
command to observe whether OSPF can receive the TE
LINK establishment message.
3) Perform the display ospf peer command to check that OSPF neighbors are established
correctly.