Installing the lbb or raid controller – Grass Valley PFR 500/E Dec 12 2002 User Manual

Page 44

Advertising
background image

Chapter 3 Servicing the PFR500/E

44

PFR 500/E Instruction Manual

20 September 2002

4. Unseat the module by pushing down on the two ejector levers.

5. Pull the module out of the chassis.

Installing the LBB or RAID Controller

Before installing the replacement RAID Controller or LBB, ensure it has the same
microcode version as the module being replaced. Otherwise, the replacement module
will not initialize.

NOTE: Removing or inserting the RAID Controller or LBB causes approximately
a 10 second loss of video (record/play). This happens regardless of whether you are
exchanging the primary controller or the secondary controller.

To install the LBB or RAID Controller:

1. Insert the replacement module into the empty bay. Make sure the module is seated.

2. Push up the two ejector levers to seat the module.

3. Tighten the captive screws.

4. Reconnect cabling.

5. Verify module initialization using rear panel status LEDs. Refer to

“Interpreting

rear panel status LEDs” on page 38

. If the replacement module fails to initialize, it

may have the wrong microcode version installed. Refer to Chapter 3, “Working
with Storage Using GVG Disk Utility”, in the Profile XP System Guide for
information on checking and loading controller firmware.

6. Check module status using NetCentral or GVG Disk Utility.

Advertising