7.6
TIMING / GENLOCK ALIGNMENT
When source signals are fed into the switcher, it must be ensured that the time dif-
ference between the sources is not outside the operating range of the internal swit-
cher autophasers. The output signals of the sources must correspond to the timing
customary in operation. For instance, no EE picture in a VTR, PB-Ref on CCVS etc.
The switcher’s Genlock Phase can be adjusted to the fed reference signal in the
range of - 12 lines to + 12 lines.
Autophasing
M/E2
> 0.5 line
Min delay
Aux outputs
Timing reference diagram SH-2-BM and SH-2S-BM
M/E3
M/E1
PP / ME3 outputs, PVW
< 0.5 line
Total timing position with respect to the reference blackburst
approx minus 12 lines
approx plus 12 lines