HEIDENHAIN TNC 122 Technical Manual User Manual
Page 14

4/97
TNC 122
8 Pin Layout
13
X41
TNC 122
Connection-assignment
TNC 121
continued
Contact
Contact
34
O14 M04 right spindle ON/ M05 OFF or High=M16/
Low=M17
35
O12 M08 coolant ON/ M09 OFF
36
O10 High=M22/ Low=M23 or M09
37
O8 High= M26/ Low=M27
38
O6 High=M32/ Low= M33
39
24 V for neg. traverse direction output
12
40
24 V for rapid traverse output
10
41
24 V for Z axis enable output
17
42
24 V for Y axis enable output
19
43
24 V for X axis enable output
21
44
24 V for “manual“ / “not manual“ output
15
45
“Not manual” output (inverted O0)
14
46
not assigned
47
Feed rate override 0 V
3
48
Feed rate override 15 V
5
The assignments are in accordance with the PLC Standard Program Id. Nr. 277 938 13!
The 24 Vdc power supply is monitored for reverse polarity and overvoltage. Reverse
polarity blows a fuse (F 2.0 A). Overvoltage above 47 V destroys the damping diode and
blows the fuse. Maximum current load is 300 mA.
PLC outputs: Inductive loads are permitted only with anti-surge diode!
Change of the I/O assignment only if Program 205 430 is active:
With the M functions M02 an M30 the output is switched to zero. Through the M function M36 the
output O5 is switched to 1 and is used to start the erosion process. Through input I2 the function
M36 is acknowledged and indicates that erosion has ended. In this case the feed-rate potentiometer
is without function.