HEIDENHAIN TNC 122 Technical Manual User Manual

Page 31

Advertising
background image


30

TNC 122

9 Machine Integration

4/97

When the axes reach the positioning window, markers M2008 to M2010 are set.

MP1030

Positioning window
Entry range: 0.001 to 2.000 [mm]

MP1030.0

Axis X

MP1030.1

Axis Y

MP1030.2

Axis Z

Encoder monitoring

Monitoring of the encoder signals must be activated with MP31.
If the signal amplitude is faulty the following error messages can appear:

ENCODER <axis> DEFECT

If the signal amplitude is no longer being evaluated

AMPL <axis> TOO SMALL

If the signal amplitude is too small

OVERLOAD <axis>

If the signal amplitude is too large

MP31

Monitoring of the amplitude of the encoder signals
Input values: 0 to 7

Bit 0

Axis X

+0 = no monitoring
+1 = monitoring active

Bit 1

Axis Y

+0 = no monitoring
+2 = monitoring active

Bit 2

Axis Z

+0 = no monitoring
+4 = monitoring active

Advertising