30
TNC 122
9 Machine Integration
4/97
When the axes reach the positioning window, markers M2008 to M2010 are set.
MP1030
Positioning window
Entry range: 0.001 to 2.000 [mm]
MP1030.0
Axis X
MP1030.1
Axis Y
MP1030.2
Axis Z
Encoder monitoring
Monitoring of the encoder signals must be activated with MP31.
If the signal amplitude is faulty the following error messages can appear:
ENCODER <axis> DEFECT
If the signal amplitude is no longer being evaluated
AMPL <axis> TOO SMALL
If the signal amplitude is too small
OVERLOAD <axis>
If the signal amplitude is too large
MP31
Monitoring of the amplitude of the encoder signals
Input values: 0 to 7
Bit 0
Axis X
+0 = no monitoring
+1 = monitoring active
Bit 1
Axis Y
+0 = no monitoring
+2 = monitoring active
Bit 2
Axis Z
+0 = no monitoring
+4 = monitoring active