3 specifications – HEIDENHAIN ND 100 User Manual User Manual
Page 108

108
2 Installation and Specifications
2.3 Specifications
2.3 Specifications
Specifications
Axes
2 to 3 axes
Encoder inputs
TTL encoders, 5 V
Display
Monochrome display for position values, dialogue, and input display, graphic functions,
graphic positioning aid
14.48 cm
1.27 cm display digit size
0.00001 mm Resolution
Error compensation
Linear (LEC), segmented linear (SLEC) and nonlinear (NLEC)
Data interface
USB (type B) 115 200 baud
Accessories
Tilting base (ID 625491-01)
Mounting arm (ID 382893-01)
Mounting frame (ID 647702-01)
QC-Wedge communication software (ID 709141-01)
Power input
AC 100 V ... AC 240 V (–15 % to +10 %)
50 Hz ... 60 Hz (±2 %)
max.54 W
Replaceable fuse
T500 mA / 250 V, 5 mm X 20 mm
Environmental conditions
Meets standards for normal environmental conditions.
Operating temperature
0 °C ... 45 °C
Storage temperature
-20 °C ... 70 °C
Installation category
II
Protection EN60529
IP40, IP54 front panel
Enclosure
Benchtop; cast-metal enclosure
Weight
2.6 kg