8.7 A

d

ditional F

unctions

D19 PLC: Transfer values to the PLC

The function D19 transfers up to two numerical values or Q parameters
to the PLC.

Increments and units: 0.1 µm or 0.0001°

Example: Transfer the numerical value 10 (which means 1 µm or
0.001°) to the PLC

Touch probe cycles, 990

1

-

Approach behavior:
0 = standard behavior
1 = effective radius, set-up clearance is zero

2

-

0 = probe monitoring off
1 = probe monitoring on

Execution status, 992

10

-

Block scan active
1 = yes, 0 = no

11

-

Search phase

14

-

Number of the last FN14 error

16

-

Real execution active
1 = execution , 2 = simulation

Group name, ID number

Number

Index

Meaning

N56 D19 P01 +10 P02 +Q3 *