Rs-422/v.11 interface, Ethernet interface rj45 socket – HEIDENHAIN iTNC 530 (340 49x-03) ISO programming User Manual
Page 644

644
14 Tables and Overviews
14.2 Pin La
y
o
ut and Connecting Cable f
o
r the D
a
ta Int
e
rf
aces
RS-422/V.11 interface
Only non-HEIDENHAIN devices are connected to the RS-422
interface.
Ethernet interface RJ45 socket
Maximum cable length:
Unshielded: 100 m
Shielded: 400 m
The interface complies with EN 50 178 for “low voltage
electrical separation.”
The pin layouts on the TNC logic unit (X28) and on the
adapter block are identical.
TNC
Connecting cable 355
484-xx
Adapter block
363 987-01
Female
Assignment
Male Color
Female
Male
Female
1
RTS
1
Red
1
1
1
2
DTR
2
Yellow
2
2
2
3
RXD
3
White
3
3
3
4
TXD
4
Brown
4
4
4
5
Signal GND
5
Black
5
5
5
6
CTS
6
Violet
6
6
6
7
DSR
7
Gray
7
7
7
8
RXD
8
WH/GN
8
8
8
9
TXD
9
Green
9
9
9
Hsg.
Ext. shield
Hsg.
Ext.
shield
Hsg.
Hsg.
Hsg.
Pin
Signal
Description
1
TX+
Transmit Data
2
TX–
Transmit Data
3
REC+
Receive Data
4
Vacant
5
Vacant
6
REC–
Receive Data
7
Vacant
8
Vacant