Using Fixed Cycles
2.2 Pr
ogr
a
m Def
a
ults f
o
r Cy
cles
Global data for probing functions
U
Set-up clearance
: Distance between stylus and workpiece surface
for automated approach of the probing position
U
Clearance height:
The coordinate in the touch probe axis to which
the TNC traverses the touch probe between measuring points, if the
Move to clearance height
option is activated
U
Move to clearance height
: Select whether the TNC moves the
touch probe to the set-up clearance or clearance height between the
measuring points
Applies to all Touch Probe Cycles 4xx.