2 datum slot center (cycle 408, din/iso: g408), Cycle run, Datum slot center (cycle 408, din/iso: g408) – HEIDENHAIN TNC 640 (34059x-02) Cycle programming User Manual

Page 420

Advertising
background image

Touch Probe Cycles: Automatic Datum Setting

16.2 DATUM SLOT CENTER (Cycle 408, DIN/ISO: G408)

16

420

TNC 640 | User's Manual Cycle Programming | 5/2013

16.2

DATUM SLOT CENTER (Cycle 408, DIN/
ISO: G408)

Cycle run

Touch Probe Cycle 408 finds the center of a slot and defines its
center as datum. If desired, the TNC can also enter the coordinates
into a datum table or the preset table.

1 The TNC positions the touch probe at rapid traverse (value from

FMAX column) following the positioning logic (See "Executing
touch probe cycles", page 392) to the st
arting point

1

. The TNC

calculates the touch points from the data in the cycle and the
safety clearance from the

SET_UP column of the touch probe

table.

2 Then the touch probe moves to the entered measuring height

and runs the first probing process at the probing feed rate
(column

F).

3 Then the touch probe moves either paraxially at measuring

height or at clearance height to the next starting point

2

and

probes the second touch point.

4 Finally the TNC returns the touch probe to the clearance height

and processes the determined datum depending on the cycle
parameters Q303 and Q305 (See "") and saves the actual values
in the Q parameters listed below.

5 If desired, the TNC subsequently measures the datum in the

touch probe axis in a separate probing.

Parameter number

Meaning

Q166

Actual value of measured slot width

Q157

Actual value of the centerline