5. Remove the cables from terminals X21 and X22

on the power supply assembly. To do this, open
the locking levers on the terminals.

6. Open the swivel nut of the cable glands and remove the cables from the SMA String-Monitor.
7. Seal the cable glands using sealing plugs.
8. Release the spacer bolts on the power supply assembly.
9. Remove the power supply assembly from the electronic assembly.

10. Replace the lower protective cover of the SMA String-Monitor (see SMA String-Monitor

manual).

11. Switch the SMA String-Monitor back on (see SMA String-Monitor manual).

7 Technical Data

Overvoltage Protection Set and Power Supply Assembly for the External
Supply Voltage 230 V

AC

for SMA String-Monitors

Terminal

Terminal

Spring-cage terminal with actuation lever on the

electronic assembly

Conductor cross-section

1.5 mm

2

to 2.5 mm

2

Cable gland

M25

Sealing range of cable gland

9 mm to 18 mm

Conductor cross-section of functional grounding

6 mm

2

Cable gland

M16

Sealing range of cable gland

3.5 mm to 10.0 mm

Recommended cable type

NYY-O

Electrical Data

External supply voltage

230 V

AC

±20%

Frequency

50 Hz

Maximum nominal current

0.3 A

7 Technical Data

SMA Solar Technology AG

Installation Manual

SSMU-AUX-PB/OVP-IA-xx-10

32

ENGLISH