SMA WB 5000 Installation User Manual
Page 30
Advertising
![background image](/files/819152/content/doc030.png)
Installation
SMA
Technology AG
Page 30
WB50_60-11:SE4005
Installation Guide
5.
Connect the mains cable as shown in the figure.
Use the supplied cable feed-through. "L" and
"N" must not be swapped.
"L" and "N" connection
6.
Fix the enclosure cover of the Windy Boy 5000 / 6000 and tighten the six
screws evenly. Do not forget the washers. The indentations of the washers must
face toward the enclosure cover.
Do not switch the line circuit breaker on yet! The Sunny Boy 3800
may only be connected to the AC grid once the DC cables are
connected and the device is securely closed.
N
L1
230 Vac:
L
N
Advertising