Terminal functions, Table 4, For a de – Yaskawa 1000 Series Drive Option - Analog Input User Manual

Page 21: 5 installation procedure

Advertising
background image

5 Installation Procedure

YASKAWA ELECTRIC

TOBP C730600 38C 1000-Series Option AI-A3 Installation Manual

21

Terminal Functions

Table 4 Option Terminal Functions

Terminal

Function

Signal

Level

Description

Voltage/Current

DIP switch

Linear

Accuracy

V1

<1> Default setting is for voltage input.

<2> At an ambient temperature of 25 °C (77 °F).

Analog signal

input 1

-10 to 10 V

or

4 to 20 mA

• Input terminals for an analog voltage or

current signal from voltage/current

reference source

• Use jumpers S1, S2, and S3 to select the

type of input signal

<1>

S1

±0.1% F.S.

<2>

V2

Analog signal

input 2

S2

V3

Analog signal

input 3

S3

AC

Common

Common for analog voltage/current input

FE

Ground

Used for grounding shielded lines

Advertising