4 Option Components

YASKAWA ELECTRIC TOBP C730600 29G 1000-Series Option JVOP-180 Installation Manual

15

Option LED Status Indicators

Connecting the Option to A1000 or V1000

Table 7 LED Status and Meaning

Figure 3

Figure 3 RUN LED Status

Figure 4

Figure 4 RUN LED and Drive Operation

LED

Illuminated

Flashing

<1>

<1> Refer to

Figure 3

for the difference between “flashing” and “flashing quickly”.

Flashing Quickly

<1>

Off

When the option is
selected for Run
command and
frequency reference
control (LOCAL).

When a device other
than the option is
selected for Run
command and
frequency reference
control (REMOTE).

During run.

• During deceleration to

stop.

• When a Run

command is input and
the frequency
reference is 0 Hz.

• During deceleration

when a Fast Stop
command was
entered.

• During stop by

External Fault digital
input.

During stop.

Examples

RE

LO

RUN

Flashing

quickly

Flashing

ON

ON

ON

ON

ON

ON

1 s

Drive output frequency

During stop

Frequency setting

OFF

ON

Flashing

OFF

OFF

RUN LED

STOP

STOP

RUN

0 Hz

6 Hz

RUN

/

RUN

STOP