8 Option Fault Diagnostics

8

Option Fault Diagnostics

Error Code and Connection Messages

Fault/Error code text will appear on the option display to indicate a specific fault. The fault

codes in

Table 14

are displayed on the LED operator and/or the option displays. For

information on the fault codes not listed in

Table 14

, refer to the unit manual.

When an option fault occurs, ensure that the communication cable is properly connected to

the option and it is not loose.
Contact your nearest Yaskawa representative or sales department if the cable appears to be

connect properly but still no message appears to indicate the error.

Note: If A1000, D1000, or R1000 is used, the fault codes are displayed on the option only.

Table 14 Fault/Error Code Displays

LCD Operator

LED Operator

(V1000)

Description

<1>

Option is connected
This is not an error message.

. . . . .

This is not an error message. Occurs when the option is connected
to the unit.

LCD Operator

LED Operator

(V1000)

Description

CPF00

COM-ERR (OP&INV)

<1>

LCD Operator Option Communication Error 1
Occurs when the unit cannot communicate with the option within
5 seconds after the power is switched on.

Cause

Possible Solution

Communication cable between the option and
the unit is not properly connected.

Remove and reconnect the option.

Problem with the option.

Replace the option.

Problem with the control circuit in the unit.

• Cycle power to the unit.
• Replace the unit.

LCD Operator

LED Operator

(V1000)

Description

CPF01

COM-ERR (OP&INV)

<1>

LCD Operator Option Communication Error 2
Occurs when the unit does not respond to the option for longer
than 2 seconds.

Cause

Possible Solution

Connector on the option cable is loose or
damaged.

Remove and reconnect the option.

Problem with the option.

Replace the option.

Problem with the control circuit in the unit.

• Cycle power to the unit.
• Replace the unit.