2.4 Mounting NS600/NS601

Mount an NS600/NS601 on a SGDH SERVOPACK in the following manner. Provide the
screws for connecting ground wire as shown below.

1. Remove the connector cover mounted on CN10 of SERVOPACK.

Mounting

Method

SERVOPACK Type

Screw

Remarks

Base
mounted

SGDH-A3 to 02BE
SGDH-A3 to 10AE

M3

×

10 round head screws

(with spring washer and
plain washer)

Attachments.

SGDH-15 to 50AE
SGDH-05 to 30DE

M4

×

10 round head screws

(with spring washer and
plain washer)

Attachments.

SGDH-60 to 1EAE
SGDH-60 to 1EDE

M4

×

8 round head screws

(with spring washer and
plain washer)

Use the screw of the front panel.

Rack
mounted

SGDH-A3 to 02BE-R
SGDH-A3 to 50AE-R
SGDH-05 to 30DE-R

M4

×

6 round head screws

(with spring washer and
plain washer)

Attachments.
Note: Make sure that spring washers and
plain washers are used for mounting.
(Otherwise, the screw for connecting
ground wire sticks out from the other
side of the flange, and the SERVO-
PACK cannot be mounted properly.)

Duct
ventilated

SGDH-60 to 1EAE-P
SGDH-60 to 1EDE-P

M4

×

8 round head screws

(with spring washer and
plain washer)

Use the screw of the front panel.

MODE/SET

DATA/

CHARGE POWER

SGDH-

SERVOPACK

YASKAWA

CN10

SERVOPACK

Connector

cover

Advertising