7 measures to satisfy the emc directive, 1 serial communication cable, 2 the core on the cable – Yaskawa AC Servo Drives Sigma II Series INDEXER User Manual

Page 22

Advertising
background image

E-20

7 MEASURES TO SATISFY THE EMC DIRECTIVE

This section describes the measures required for the NS600/NS601 to conform to EMC Direc-
tive (EN50081-2, EN50082-2).

7.1 Serial Communication Cable

Use the twisted pair shielded cable.

7.2 The Core on the Cable

Attach the core on the cable as shown below:

Cable line and the line position where the core are attached are shown below.

Note: For details on the SERVOPACK core and the line filter, refer to the

Σ-II series SGDH Instruction Manual” (TOB-S800-32).

Core Model

ESD-SR-25

Quantity

1

Turn

2

Manufacturer

Tokin Corp.

Cable

Core

Cable Name

Mounting Position of Core

Serial Communication Cable

Near the host controller and the SERVOPACK side