7 MEASURES TO SATISFY THE EMC DIRECTIVE
This section describes the measures required for the NS600/NS601 to conform to EMC Direc-
tive (EN50081-2, EN50082-2).
7.1 Serial Communication Cable
Use the twisted pair shielded cable.
7.2 The Core on the Cable
Attach the core on the cable as shown below:
Cable line and the line position where the core are attached are shown below.
Note: For details on the SERVOPACK core and the line filter, refer to the
“
Σ-II series SGDH Instruction Manual” (TOB-S800-32).
Core Model
ESD-SR-25
Quantity
1
Turn
2
Manufacturer
Tokin Corp.
Cable
Core
Cable Name
Mounting Position of Core
Serial Communication Cable
Near the host controller and the SERVOPACK side