7.4 Wiring Examples

The following diagrams show the wiring example. Before wiring, turn off the power on/off
switch and post a notice of “No Conduction.” Only an electrical expert can perform the wir-
ing. The noise filter and the core are shown in the diagram.

Note: 1. Clamp: Secure cable shields and ground for conductive metal parts.

2. Make sure that the grounding plate are securely connected to the grounding.
3. Remove the paint from the grounding plate to insure a good Earth connection for filter,

SERVOPACK, clamp, etc.

L1,L2,L3

A1,A2

U,V,W,

CN2

CN7

CN1

Control box

Grounding plate/Box

<Required EN Specifications>

Core

SGDH
SERVOPACK

NS600
/NS601

Encoder

Motor

Servomotor

Host controller

Clamp

Core

Core

Core

Core

Core

Clamp

Clamp

Clamp

Clamp

Clamp

AC/DC

converter

Noise
filter 1

Noise
filter 2

Control
power
supply

Single-phase
200 VAC

Main
power
supply

Three-phase
400 VAC

Core

Clamp

Open