3.3 Orientation
Install the SERVOPACK perpendicular to the wall as shown in the figure below.
The SERVOPACK must be orientated as shown in the figure.
Firmly secure the SERVOPACK through two to four mounting holes depending on the SER-
VOPACK capacity.
3.4 Installation Precations
When installing multiple SERVOPACKs side by side in a control panel, observe the follow-
ing installation method:
Front Panel
Install SERVOPACK perpendicular to the wall so that the front panel (digital operator
mounted face) faces outward.
MADE IN JAPAN
Ventilation
Mounting face
Cooling fan
30 mm (1.2 in) min. 10 mm (0.4 in) min.
50 mm (2 in) min.
50 mm (2 in) min.
Cooling fan