3.3 Orientation

Install the SERVOPACK perpendicular to the wall as shown in the figure below.

The SERVOPACK must be orientated as shown in the figure.

Firmly secure the SERVOPACK through two to four mounting holes depending on the SER-
VOPACK capacity.

3.4 Installation Precations

When installing multiple SERVOPACKs side by side in a control panel, observe the follow-
ing installation method:

„

Front Panel

Install SERVOPACK perpendicular to the wall so that the front panel (digital operator
mounted face) faces outward.

MADE IN JAPAN

Ventilation

Mounting face

Cooling fan

30 mm (1.2 in) min. 10 mm (0.4 in) min.

50 mm (2 in) min.

50 mm (2 in) min.

Cooling fan