Yaskawa DS387 User Manual

Page 8

Advertising
background image

B5. For VCD 703, all input selection jumpers on
the AI–14B board must be set to "V" (see Figure
B2).

B6. Wiring. See Figure B3 for Analog Speed
Reference connections. See Table B2 for
terminal functions.

CAUTION

KEEP ANALOG SPEED REF. (I.E. CONTROL CIRCUIT) WIRING
SEPRATE FROM MAIN CIRCUIT INPUT/OUTPUT WIRING.

CAUTION

TO PREVENT ERRONEOUS OPERATION CAUSED BY NOISE
INTERFENCE, USE SHIELDED CABLE FOR CONTROL WIRING, AND
LIMIT DISTANCE TO 10M (33 FEET) OR LESS.

CAUTION

IF ANY OF THE CONTROL SIGNAL INPUT TERMINALS (TC1 THRU TC3)
ARE NOT USED, JUMPER THEM TO 0V TERMINAL (TC4).

IMPORTANT

Because the analog speed reference is converted by 1/16384 resolution, the voltage
source accuracy of the analog speed reference source must be con-sidered. To
ensure speed control accuracy, use a high precision power supply for the voltage
source.

Route wires from the drive and connect to the peripheral device. Refer to "Electrical Installation" in the drive
technical manual for further information on use of shielded cable.

Figure B2. Voltage/Current Selection on AI-14B

• • •

V C

• • •

V C

• • •

V C

PART OF

AI-14B

BOARD

ALL JUMPERS

(SHORTING

PLUGS) SHOWN

IN POSITION

FOR VOLTAGE

INPUT

Table B2. Terminal Functions of AI-14B

Terminal

Function

Signal Level

Notes

TC1

Analog voltage input

Voltage Input:

— Input Resolution:

Input voltage: 0 to ±10V/0 to ±100%

Voltage: 1/8192 (13 bits) plus

TC2

Analog voltage input

Input impedance: 20K

sign (polarity)

TC3

Analog voltage input

— Signal Linearity: ±0.1%

— Terminal screws are metric

TC4

Signal common

0V

size M3.

Yaskawa Electric America, Inc-www.drives.com

02Y00025-0296 Page 8 OF 14

REL. 08/23/91

ANALOG SPEED REFERENCE

(BIPOLAR) (AI-14B) MODEL DS387