Yaskawa CM093 User Manual

V7 ethernet/ip option kit cm093, Warning

Advertising
background image

V7 EtherNet/IP Option Kit

CM093

Yaskawa Electric America, Inc. –

www.yaskawa.com

IG.V7.26, Page 1 of 11

Date: 05/24/2010 Rev: 10-05

1. Applicable products: Standard V7 drives CIMR-V7AM*) with Ethernet

specific software installed (not V74X or V7N). Check V7 monitor U-10 or
the PRG # on the V7 nameplate for version 8340 or 8350 software.
Note:
To order a V7 with Ethernet software, use the following part number
format: CIMR-V7AM****1-057.

2. When using this Kit, it is strongly recommended that no connections be

made to the V7 drive's DC Bus terminals (+1 and -) on models CIMR-
V7AMxxxx1, where xxxx is 25P5, 27P5, 45P5, or 47P5. A connection for
a DC reactor (+1 to +2) or braking resistor (B1 to B2) is allowed.

3. Unpack the V7 EtherNet/IP Option Kit and verify that all components

are present and undamaged.

4. Connect power to the V7 and verify that it functions correctly. This

includes running the V7 from the operator keypad. Refer to the V7 Technical
Manual
, TM.V7.01, for information on connecting and operating the V7
drive.

5. Remove power from the V7 and wait for the charge lamp to be

completely extinguished. Wait at least five additional minutes for the V7 to
be completely discharged. Measure the DC bus voltage and verify that it is at
a safe level.

6. Remove the operator keypad and V7 drive cover.

a. Remove the terminal cover by removing the retaining screw and lifting

out the cover.

b. Remove the operator keypad.

7. Remove the CN2 cover from the V7 terminal housing. Carefully snip the

3 tabs connecting the CN2 cover on the V7 housing and remove the cover.

8. Attach the Mounting Bracket. Align the mounting bracket as shown in the

figure to the right. Secure the mounting bracket to the V7 drive’s housing
using the M3 x 8 screw.

9. Wire the V7 drive I/O terminals prior to mounting the V7 EtherNet/IP

Option Kit as the option will obscure the power and control terminals when
mounted.

10. Mount the V7 EtherNet/IP Option Kit on the V7 drive.

a. Do NOT connect a ground wire to the screw on the back of the option kit.
b. Align the CN1 connector on the back of the option with its mating CN2

connector on the front of the V7 drive.

c. Simultaneously align connector CN3 (male RJ-45) on the back of the

option with connector CN1 (female RJ-45) on the front of the V7 drive.

d. Align the tabs on the option with their corresponding slots on the front of

the V7 drive.

e. Press the option and the V7 drive together until the tabs lock into their

associated slots.

f.

Secure the option to the V7 drive by tightening the locking screw at the
top-center of the option.

g. Reinstall the operator keypad and all V7 covers.

CM093 EtherNet/IP Option Kit Parts

Qty.

V7 EtherNet/IP Option Kit CM093

1

Option Mounting Bracket

1

Mounting Bracket Screw (M3 x 8)

1

Ferrite (Power and Motor Leads)

2

Ferrite (Ethernet Cable)

1

Cable Ties

3

Installation Guide (IG.V7.26)

1

WARNING

Dangerous voltages in excess of 400VDC (230V drives) or 800VDC
(460V drives) are present at the DC bus terminals of the drive.